История страницы
Create context with Robin OCR 2 Version
...
5 (Python)
Action group: Robin OCR
...
Description
The action creates a context for working with Robin OCR 2.
Action parameters
Example of an address: http://testhost:8080/api/v1/ocr/gettext/abt
The "Language" field by default - English - you need to specify the intended language of the text.
The "Protocol" field by default - http - specifies the standard describing the rules of interaction between functional blocks during data transfer.
The "Server address" field by default - 127.0.0.1 - specifies a unique identifier that allows you to determine the physical location of the server and provides the ability to connect to it through the network.
The "Port" field by default - 8080 - specifies the numeric identifier of the program or workflow that services network connections at the specified network address (IP address).
The "API Version" field by default - 1 - specifies the requested server version.
The "Function" field by default - ocr/gettext/abt - specifies the parameters that determine what action can be performed on the document.
The "Result" field - Robin OCR 2 instance.
- If the user's port 8080 is busy, another free port must be specified.
- At the moment only one function - ocr/gettext/abt (Array of text with coordinates) and one server version are implemented.
The action will generate an error if you cannot connect to a server with a runtime system with the specified parameter values. Error description: "Incorrect data are specified for connecting to the server of the recognition system and working with it.".
Settings
actions in the "ROBIN" subgroup.
Action icon
Parameters and their settings
Property | Description | Type | Filling example | Mandatory field |
Parameters | ||||
Language | The intended language of the text to be extracted |
Robin.String | No | ||
Protocol | Data transfer protocol. The default value is «http» |
Robin.String | No | ||
Server address | The name or IP address of the device on which the recognition system is installed. The default value is «127.0.0.1» |
Robin.String | No | ||
Port | The port for the server. Filled in by the user only if port 8080 is occupied by another server. The default value is «8080» |
Robin.Numeric | No | ||
API Version | Server version. The default value is «1» |
Robin.String | No | ||
Function | Function that defines what action can be performed on the document. The default value is «ocr/gettext/abt» |
Robin.String | No | |||
Results | ||||
Result | Action context for working with Robin OCR |
Robin. |
OCR |
Special conditions of use
...
- If the user's port 8080 is busy, another free port must be specified.
- At the moment only one function - ocr/gettext/abt (Array of text with coordinates) and one server version are implemented.
The action will generate an error if you cannot connect to a server with a runtime system with the specified parameter values. Error description: "Incorrect data are specified for connecting to the server of the recognition system and working with it".
Example of use
Recognize license plate number from the image
...
- Assemble a robot scheme consisting of actions:
- Set the parameters of the "Create context with Robin OCR 2 " action.
- Set the parameters of the "Extract text from file" action.
- Click on the "Start" button in the top panel.
The program robot worked successfully. The license plate number has been recognizedcompleted successfully.
The file with overlaid blocks is saved to the specified folder.
...